fix(marmot-interop): clean up daemons on Ctrl+C in interactive harness
Apply the same SIGINT/SIGTERM/SIGHUP trap hardening to the interactive harness that just landed on the headless one. Without it, killing the script mid-run leaves the nohup'd wn daemons alive and the next run fails in preflight because the sockets are still held.
This commit is contained in:
@@ -925,7 +925,20 @@ test_14_push_notifications() {
|
||||
# ==== main ===================================================================
|
||||
|
||||
main() {
|
||||
trap 'stop_daemons; print_summary' EXIT
|
||||
# Make sure Ctrl+C / SIGTERM / SIGHUP all run the full cleanup path —
|
||||
# otherwise wnd is nohup'd and keeps running after the script dies.
|
||||
# Trap INT/TERM/HUP forces `exit`, which triggers the EXIT handler once.
|
||||
cleanup() {
|
||||
local rc=$?
|
||||
trap - EXIT INT TERM HUP
|
||||
stop_daemons
|
||||
print_summary
|
||||
exit "$rc"
|
||||
}
|
||||
trap cleanup EXIT
|
||||
trap 'exit 130' INT
|
||||
trap 'exit 143' TERM
|
||||
trap 'exit 129' HUP
|
||||
banner "Amethyst <-> whitenoise-rs interop harness ($RUN_TS)"
|
||||
|
||||
preflight
|
||||
|
||||